New Deck #6: Finishing the deck surface and fixing the electric problems

Blog entry by Karson posted 204 days ago 348 reads 0 times favorited 5 comments Add to Favorites
« Part 5: Treated Wood Part 6 of New Deck series Part 7: Well the first bench is done. »

Well I finally got the electric problems taken care of and so i screwed down the last two deck boards. These boards butt up against the two light poles. And I did the finish cutting of the curve.

So here are the details:

I mentioned earlier, I believe in the first blog of this series that I installed a GFCI circuit breaker in the fuse panel and i was having problems where it kept tripping whenever i put a load on the circuit. Even a load as small as a Dusk to Dawn switch with nothing else.

LumberJock Richard Williams stated that he wished that he was closer so that he could find my problem. Without me paying his plane fare from Las Vegas I did the next best think. I asked him for his phone number so I could call. He replied. I called.

I told him all of the things that I had tried and that had failed. He suggested a couple of things to try. Verfy that the bare ground wire was not touching the white wire anywhere in the circuit. (I didn’t think I had that problem) Replace the buss bar that was in the circuit sub panel. (Mine was very rusty). This discussion was going on in a 3” rain storm, so I was not too interested is stepping outside at that moment.

The next day I was returning home from taking my son to school, and I was running the circuit through my mine. One of the things that Richard has said was that a GFCI breaker is measuring the amount of current that was going through the black (hot) wire and then checking that the reverse of that was going through the neutral wire (white) of the other wave of the alternating current. (These are my words and not necessarly his exact words). I was wondering in my mind about how that was working on the circuit that I had installed.

I then realized that I might have hooked it up incorrectly. (I had never read the instructions, Because I assumed that it was hooked up the same as a regular circuit breaker.) I had hooked up the black wire to the GFCI breaker. I was suppose to also hook up the white wire to another terminal on the GFCI breaker. I had failed to do that. So what was happening was that any load that I put on the black wire was not being offset through the white wire, because I had not attached it to the GFCI breaker.

When I removed the white wire from the buss bar and attached it to the correct terminal on the GFCI breaker, my circuit worked as designed. The Dusk to dawn switch does not trip it, a light bulb does not trip. (I have not put my finger across the terminal to see if it does trip it. Like a SawStop you hope it works)

Once I got all of the electric wiring problems I screwed down the final two deck boards

I cut the angle off the deck to match the sidewalk around the Solarium.

I measured the curve for the end of the deck. I found that it was a 22’ radius. So I had my wife hold the tape measure and I inscribed the curve with a pencil. I then used my Bosch Jigsaw to cut the curve to the line that I had drawn.

We set up a table and chairs and had supper tonight on the deck. It was chilly but we didn’t care.

The supervisor checking to see if we left any scraps on the deck. (As if anything would get as far as the deck surface when he’s hanging around)

So now on to the benches.

-- Karson retired in DE e-mail karson_morrison@bigfoot.com

View Karson's profile

Karson

52 posts in 375 days

Entry tags/keywords

deck electric problems gfci

View Blog Archive
Subscribe to blog entries (RSS)


By subscribing to the RSS feed you will be notified when new entries are posted on this blog.

Recent Entries


5 comments so far

View Damocles's profile

Damocles

805 posts in 350 days
hardiness zone 5

posted 204 days ago

Excellent! I also like the lights you have on the corners…well done Karson!

-- Living on the square...Metro Detroit

View MsDebbieP's profile

MsDebbieP

3776 posts in 496 days
hardiness zone 5b

posted 203 days ago

sweet
you did an amazing job. And it’s done already!

-- - Debbie, SW Ontario Canada (USDA Hardiness Zone: 5a)

View Bon's profile

Bon

1705 posts in 276 days
hardiness zone 5a

posted 203 days ago

Looking really good Karson.Nice job.

-- Bon,Hastings,Ont.....zone 5a....Always room for one more

View Bunting's profile

Bunting

587 posts in 220 days
hardiness zone 5b

posted 200 days ago

I don’t know the first thing about carpentry or electrical

But you sure did a beautiful job

I love it

-- NS Zone 5B 200 KM East of Halifax cheers Bunting------Having a place to go – is a home. Having someone to love – is a family.

View GrandmaT's profile

GrandmaT

3182 posts in 374 days
hardiness zone 5

posted 200 days ago

Beautiful, just beautiful!!!

-- "A perfect garden is just a garden to be in-perfection. Mornings to work on it and evenings to pause and look at it." Southeast Michigan, Zone 5a/5b

You must be signed in to post the comments.

Your Online Garden - Your Support Is Greatly Appreciated - Your Gardening Showcase - 3 Ways To Help, Financially - Your Gardening Community

Gardening StoreApparel StoreMake a Donation
Bookmark And Share This Page
  • Advertise with us

DISCLAIMER: All views and comments posted by members are not necessarily those of GardenTenders.com or of those working on the site.

Latest Projects | Latest Blog Entries | Latest Forum Topics

LumberJocks.com :: woodworking showcase

Latest Projects | Latest Blog Entries | Latest Forum Topics

HomeRefurbers.com